Hazardous Chemical Detection

Oxidizing Gas Tester

CIT-28-10S

 CIT-28-10S oxidizing gas tester used to measure the oxidizing for a kind of gas or mixture gas, whether higher than the air oxidation, it can be used to test the toxicity and corrosive gases or mixtures of gases.

More details

More info

Product description 1) CIT-28-10S oxidizing gas tester used to measure the oxidizing for a kind of gas or mixture gas, whether higher than the air oxidation, it can be used to test the toxicity and corrosive gases or mixtures of gases. 2) comply with ISO10156-2010 "gases and gas mixtures selection of cylinder valve exhaust port by measuring the fire potential and oxidizing ability" Part IV oxidation of gas and mixed gas, GB / T27862-2011 "chemical hazard classification test methods for gas and gas mixtures potential and oxidizing ability " part 4 oxidative capacity of the combustion gases and gas mixtures. Product Features 1) The test part and control system independent design to ensure safe on instrument control unit and the laboratory personnel; 2) Supporting with PC operating software; 3) Support for remote ignition, ensure the safety of laboratory personnel; 4) Equipped with high-precision pressure sensor that can accurately measure the explosion pressure, and control gas partial pressure ratio of the concentration; 5) Equipped with a magnetic stirring device; 6) Electronic micro-processor controlled ignition time; 7) With auto cleaning function; 8) With automatic pressure relief device, after the end of the trial, you can choose automatic pressure relief to release of the test tank pressure; 9) With multiple explosion-proof function, to protect the safety of laboratory personnel 10) With automatic fault detection and automatic sound and light alarm function; 11) Testing process fully automated, without human intervention, support parameter setting, data storage, viewing reports. Product Specifications 1) Operating environment: 5 ℃ ~ 30 ℃, <85% RH 2) Test tank material: stainless steel 316L 3) Test tank maximum pressure: ≥5000Kpa 4) Test tank capacity: ≥0.005m³ 5) Test tank accessories: magnetic stirrer, stirring speed adjustable 6) Ignition system metal rod: diameter ≥3mm 7) Nickel-chromium wire diameter: 0.05 ~ 0.2mm 8) Ignition energy: 10 ~ 20J 9) Explosion pressure sensor detection range: 0 ~ 4000kPa 10) Explosion sensor pressure: ≥6000kPa 11) Explosion sensor measurement accuracy: ± 0.1% FS 12) Explosion sensor response time: ≤1ms 13) Gas sensor detection range: 0 ~ 200kPa 14) Gas sensor measurement accuracy: ± 0.1% FS 15) Temperature range: 0 ~ 150 ℃ 16) Temperature accuracy: ± 1 ℃ 17) Host Size: 830mm × 650mm × 1200mm 18) Electronic control box size: 320mm × 500mm × 500mm 19) Weight: 280kg 20) Power supply: AC220V ± 10%, 50Hz ± 3Hz 21) Rated power: 400W 22) Ignition power: 3000W

30 other products you may be interested: