SP-OF4000PG fiber is a high-resolution spectrometer, using high-resolution optical bench, for applications that require fine spectral resolution of the case for laser characterization, gas analysis and plasma absorption measurement applications provide the best spectral measurements.
High-resolution optical platform provides the highest optical resolution of 0.1nm, the focal length of 100nm and a numerical aperture of 0.11 combination can make spectrometer without increasing the volume of the case itself to achieve the best balance of resolution and sensitivity;
EX double-double blazed grating blazed gratings have over a wide spectral range more uniform response to address the broad spectrum equalizer stage efficiency and higher-order interference problems, the broadest spectrum coverage of 200-1100nm;
High-speed control technology can set a new integration time in 1ms, saving time for spectrometer control;
SP-OF4000PG high resolution fiber optic spectrometer can be equipped with a special UV-sensitizing treatment of deep ultraviolet CCD, it will be able to expand the scope of deep ultraviolet spectral detection band; while SP-OF4000PG high resolution fiber optic spectrometer has the flag and calling the underlying technology, ensure high-speed with a measurement to further enhance measurement accuracy; allows users products leading position in technology, giving the product a stronger bargaining power; with low-cost fiber optic build personalized spectral measurement equipment.
Technical Parameters
Model | 200 300 400 500 600 700 800 900 1000 | | | | | | |
Single channel | – | – | – | – | – | – |
SP-OF4000PG-EX | 200-1100 | 0.25 | 0.86 | 0.99 | 1.63 | 3.08 | 6.32 |
SP-OF4000PG | 370-1050 | 0.19 | 0.75 | 0.86 | 1.29 | 2.44 | 4.88 |
SP-OF4000PG+ | 200-650 | 0.13 | 0.49 | 0.57 | 0.81 | 1.58 | 3.16 |
SP-OF4000PG | 350-800 | 0.13 | 0.49 | 0.57 | 0.81 | 1.58 | 3.16 |
SP-OF4000PG+ | 200-345 | 0.04 | 0.12 | 0.15 | 0.27 | 0.54 | 1.09 |
5 channels | – | – | – | – | – | – |
SP-OF4000PG+ | 180-400 | 0.06 | 0.21 | 0.24 | 0.40 | 0.79 | 1.60 |
SP-OF4000PG | 395-602 | 0.06 | 0.20 | 0.24 | 0.39 | 0.81 | 1.58 |
SP-OF4000PG | 597-788 | 0.05 | 0.15 | 0.21 | 0.39 | 0.77 | 1.57 |
SP-OF4000PG | 783-955 | 0.05 | 0.15 | 0.22 | 0.38 | 0.75 | 1.50 |
SP-OF4000PG | 950-1100 | 0.04 | 0.14 | 0.21 | 0.35 | 0.68 | 1.36 |
3 channels | – | – | – | – | – | – |
SP-OF4000PG+ | 277-491 | 0.06 | 0.21 | 0.25 | 0.40 | 0.80 | 1.60 |
SP-OF4000PG | 486-685 | 0.05 | 0.19 | 0.25 | 0.38 | 0.79 | 1.58 |
SP-OF4000PG | 680-1100 | 0.12 | 0.43 | 0.53 | 0.79 | 1.58 | 3.14 |
| | | | | ±20% | (nm) | FWHM |
Notes: (1) “spacer” represents the wavelength of the detector pixel spacing; (*) indicates the value slit width in μm; (2) the resolution value is a theoretical value, the actual deviations will be 20%.
Spectral properties
| | Detection range: | 200~1100 nm,depending on the grating | Wavelength resolution: | The highest 0.04nm, based on the 1800 line grating, details can see the “model table” | Optical resolution: | The highest 0.12nm (FWHM), based on the 1800 line grating and 10 m slit ,details can see the “model table” | detector: | Toshiba,TCD1304DG,3648 pixels | Elimination of higher order diffraction: | 3 front and 4 rear filters are selected to eliminate ghost lines in the spectrum. | Optical platform: | Incident focal length100mm , f number 4.5, cross C-T | Integral time: | 4ms ~ 60s | dynamic range: | Better than 3000:1, significantly better than similar products | SNR: | Better than 400:1, when saturated | stray light: | < 0.1%,Measuring wavelength 600nm | Corrected linearity: | > 99% |
|
External interface
| | Optical fiber interface: | SMA905 | data transmission: | USB-B(square port), supports USB2.0 communication protocol, 480Mbps transmission speed | Extended function port: | 30pin extension ports, support for complex enjoy BreakOut-Board and BreakOut-Cable external expansion function | External trigger: | 4 trigger modes:Normal / Level / Edge / Synchronization |
|
Others
| | Dimension: | 157 x 115 x 41 mm³ | weight: | 0.81 kg | A/D bit: | 16 bit | Power waste: | 200mA @ 5VDC | High speed control technology: | As soon as the upper computer is given Integral time adjustment order, the new spectrum acquisition is started within 4ms. | Flag bit technology: | Provide acquisition completed flag bit for the upper computer to query |
|
Product features
· 1,High resolution optical platform to achieve the best balance between resolution and sensitivity without increasing the volume of spectrometer; | · 2,Full spectrum technology, the use of linear gradient to eliminate high order filters and variable grating, to solve the problem of wide band efficiency equalization and high order interference, the widest spectral coverage of nm 200-1100; | · 3,Ultra high resolution, providing the highest 0.1nm optical resolution; | · 4,High speed control technology, can be set in the new 1ms integration time, saving time for spectrometer control; | · 5,Flag bit technology, at any time to check the status of the spectrometer to complete the state of the spectrum, interrupted at any time to re- collect, do not need to wait for a long time; | · 6,The underlying call technology, support system integration development, to facilitate users to more quickly develop spectrometer application. |
|
Key Technology
| Full spectrum technology Using patented EX variable-blazed grating and gradual elimination of higher order filters technology to solve the wide spectral balance of efficiency and higher interference problems, the wide spectral coverage up to 200~1100nm. |
| | | | High speed spectrum transmission technology Using a high-speed CCD and high-speed processing chips and algorithms to achieve Subtle spectral detection |
| | | | Low stray light technology Low stray light technology can effectively reduce stray inside the spectrometer, internal spraying aerospace-grade high-light-absorbing material, effectively inhibit the formation of stray light. |
| | | | UV-sensitive technology Select special high stability of fluorescent substances to do CCD ultraviolet-sensitive coating, achieved deep UV detection at a lower cost. |
| | | |
|
|