Product introduction:

  1.      Fast - new immunoassay system, get results in 1 minute
  2.      Quantitative - immunoturbidimetric system, high sensitivity and wide range         detection
  3.      Reliable - full blood pressure product value correction function and serum sample dilution function
  4.      Convenient - RF non-contact reagent card, man-machine dialogue operation
  5.      CRP detection is a cost-effective indicator for the differential diagnosis of bacterial and viral infections. Continuous monitoring is of great significance for the diagnosis and efficacy monitoring of postoperative infections of other inflammatory and malignant diseases.

 

Main performance characteristics 

  1.      Detection principle: nano-amine-based microsphere immunoturbidimetric system, highsensitivity, wide inspection range;
  2.      Detection mechanism: laser type cold light source integrated design, easy to assemble and replace;
  3.      Number of channels: single channel or dual channel, independent test by project; (QR-200 is dual channel, simultaneous measurement function)
  4.      Detection method: automatic and timely detection, the test cup is automatically numbered and tested after being placed in the test body;
  5.      Detection operation: touch operation, intelligent temperature control, mixing, automatic interpretation of blanks and calculation of results;
  6.      Sample type: whole blood, plasma, serum, urine, etc., sample dilution factor can be entered and automatically converted results;
  7.      Project selection: non-contact RF type reagent card, only need to read the card once on the same item;
  8.      HCT calibration: HCT values ​​are automatically calibrated for each whole blood sample, consistent with serum results;
  9.      Output: Same screen display, printing and RS232 sync output.

 

Technical Parameters

1. Light source: 6V10W tungsten halogen lamp with a life of more than 5000 hours;

2. Wavelength range: 400~750nm;

3, filter: standard 405, 450, 490 / 492, 630nm four filters, can load eight filters;

4, blank mode: single hole blank, long empty blank, row blank, column blank;

5. Calculation method: optical density, row subtraction, column subtraction, linear, quadratic curve, cubic curve, power function, partial logarithm, four-parameter equation;

6, detection speed: single wavelength <3 seconds / 96 holes, dual wavelength <9 seconds / 96 holes

7. Measurement range: 0.0000-4.5000Abs;

8, resolution: 0.0001A

9, linearity: ± 0.5% or <0.025A

10. Repeatability: <0.1% or ±0.002A

11, channel difference: <0.01A

12. Display: embedded 8-inch touch screen color display or external LCD display, which can display the whole board sample result and calibration curve;

13, storage: more than 500 test procedures and 500 96-well plate test results, 200 kinds of ELISA plate format, more than 1,000,000 test results;

14, interface: 4 USB two-way communication port, 1 RS232 interface, 1 VGA interface, 1 keyboard interface and 1 mouse interface;

15, the environment: power supply 12VDC (100V-240V wide input); temperature, 5 ° C ~ 40 ° C; temperature, 10% ~ 90%

 