STA TGA-DSC Synchronous Thermal Analyzer

SKU: STA3000 Category:
Request a Quote

STA Synchronous thermal analysis combines TGA (Thermogravimetric Analysis) with DTA (Differential Thermal Analysis) or DSC (Differential Scanning Calorimetry), in which we can get the information of TG and DTA or DSC in synchrony using the same sample during the same operation.

APPLICATION

Widely used in research and development, process optimization and quality monitoring in various fields such as plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials

Measure and research characteris

  • DSC: Melting and crystallization, phase change, reaction temperature and heat, heat of combustion and specific heat capacity, etc
  • TG: Thermal stability, decomposition, REDOX, adsorption and adsorption, free water and gesso content, ingredients proportion computation, etc

Structural advantages

  • Furnace body is heated by double-row winding of precious metal nickel-chromium(STA2000) & Platinum rhodium(STA3000) alloy wire, which reduces interference and is more resistant to high temperatures.
  • Tray sensor is made of precious metal nickel-chromium(STA2000) & Platinum rhodium(STA3000) alloy, which has advantages of high temperature resistance, oxidation resistance, and corrosion resistance.
  • The power supply, circulating heat dissipation part is separated from the host, reducing the influence of heat and vibration on the micro-thermal balance.
  • It adopts an open-top structure, which is convenient to operate. It is difficult to move furnace body up to place sample, and it is easy to cause damage to sample rod.
  • The host adopts heat insulation device to isolate the heat influence of the heating furnace body on the chassis and the micro-thermal balance.
  • The furnace body can be replaced according to customer requirements

Advantages

  • Using imported 32bit ARM processor Cortex-M3 core, sampling speed, processing speed is faster.
  • 24bit four-channel sampling AD collects DSC signal, TG signal and temperature T signal.
  • Power supply and water circulation part are individually controlled by 8bit single-chip microcomputer to separate the host and the cooling part without interfering with each other, but the two are closely connected, and the cooling part is controlled by the host.
  • USB two-way communication is adopted between the software and the instrument to fully realize remote operation. The parameter setting of the instrument and the operation and stop of the instrument can be carried out through the computer software.
  • 7 inch full color 24bit touch screen, better man-machine interface. TG calibration can be achieved on the touch screen

 

 

Instrument interface

 

Technical parameters

ModelSTA3000
Temperature rangeRT ~1500°C
Temperature resolution0.01°C
Temperature fluctuation±0.1°C
Material of furnace & sensorPlatinum rhodium
Heating rate0.1~80°C/min
Temp. controlPID algorithm control, heating, constant and cooling
Constant temp. time0~300min arbitrarily set
Balance measuring range0.01mg~3g
Program controlMulti-stage heating control
DSC range0~±600mW
DSC resolution0.01mW
Accuracy of weighing0.01mg
Display mode24bit color, 7-inch LCD touch screen
Atmosphere devicebuilt-in gas flow meter, including two-way gas switching and flow rate control
Atmosphereinert, oxidizing, reducing, static, dynamic
SoftwareIntelligent software can automatically record TG curve for data processing and print experimental reports
Curve scanheating scan, cooling scan
Power supplyPwer supply and the weighing system have an isolation shield to avoid AC interference, AC220V 50Hz
Operating softwarecan be switched to meet the application switching test of differential display, differential heating, thermogravimetry, and synchronous heating
Communication interfaceUSB communication

Packing list

ITEM QTY
HOST1 set
U disk with software1 pc
data line2 pcs
power cable1 pc
ceramic crucible200 pcs
ceramic cover2 pcs
metal cover1 pc
raw tape1 L
Pure Tin1 bag
10A fuse5 pcs
Sample Spoon/Sample Pressure bar/Tweezers1 each
ear ball1 pc
trachea2 roots
Counterweight1 pc
sensor1 pc
manual1 pc
Warranty1 pc
certificate1 pc

Optional list

SNNAME
STAC0011Ceramic crucibles
STAC0012Aluminum crucible
STAC0013Liquid cooling module with thermostat
 

 